Facebook

WELCOME TO OUR BLOG

We're sharing knowledge in the areas which fascinate us the most
click

IP68 Sealing in Stainless Steel Hazardous Area Camera Housings

By kaidunex October 30th, 2026 69 views

Introduction: IP68 tells you a camera housing survived dust and water testing, but the seal that earns it lives at gaskets, joints and cable entries.

A stainless steel housing with an IP68 label looks like the end of the conversation. In practice it is the start of one. Two cameras can carry the same rating and behave very differently after two years on a chemical plant wall or a ship's deck, because the number summarizes a test on a complete, closed assembly, while real-world results depend on how that assembly is gasketed, tightened, and cabled. Installers and maintenance crews meet this difference first: the housing body stays sound while a gland works loose or a gasket takes a permanent set. This piece maps what the 6 and the 8 each measure, why the sealing interface carries more weight than the label, and how ingress protection sits apart from explosion protection.

What the 6 and 8 in IP68 actually test for on a camera housing

The IP code uses two digits, and each answers a separate question. The first digit covers solids, and 6 is the top of that scale: dust-tight, meaning no dust enters the enclosure. On a camera that matters more than it sounds, because fine dust reaching the lens chamber scatters infrared light and hazes night images, while grit working into the pan and tilt gears slowly turns into mechanical wear. The second digit covers water, and 8 is the immersion level, where the housing is tested under continuous submersion in conditions agreed between the maker and the test house. That phrase "conditions agreed" is where most of the useful detail hides. Continuous immersion is not one fixed depth. Depth, duration, and whether the unit runs powered are agreed per product, so two IP68 cameras can be qualified against very different water columns. A project engineer comparing housings therefore asks the depth question before assuming either unit shrugs off a jet-wash on a tank farm or a months-long soak on an open deck. On the KAIDUNEX KDQ-EX-PTZ2012IR04N(A) mini PTZ, the enclosure carries an IP68 rating with a 304 or 316L stainless steel housing; the depth and duration figures for that model come from its test file, so request them when a site specification needs the actual number.

How gasket compression, housing joints, and cable entries shape real sealing performance

The rating is decided on a complete, closed housing. Everything that opens — the front window, the body joint where the two halves meet, the port where the cable enters — is a place where the assembled unit either reproduces the tested sample or quietly departs from it. Sealing performance is therefore a build and installation property as much as a design property, and the difference shows up on inspection day rather than on a datasheet. Maintenance crews who open a camera for cleaning or repair hold that performance in their hands every single time.

1. Gasket Compression and Surface Flatness Decide Whether the Seal Holds

An elastomer gasket only seals inside a compression window. Too little squeeze and the material never fills the micro-gaps on the mating surface; too much and it takes a permanent set, splits at the corners, or bows the joint out of flat. The flange has to stay flat so the gasket loads evenly around the whole perimeter, which is one reason a rigid machined stainless flange behaves better than a thin sheetmetal joint across years of thermal cycling. The field evidence is easy to read. A gasket that springs back when the cover lifts is healthy; one that stays flattened, cracked, or stuck to a single face has already lost its memory, and that joint will pass water on the next heavy rain however carefully it is retightened.

2. Cable Entry Points Often Become the Weakest Sealing Interface

Every cable entering a housing passes through a gland, and that gland is a second seal with rules of its own. It has to match the cable jacket diameter, engage enough thread to compress its sealing ring, and provide strain relief so cable movement stops at the gland rather than reaching the terminals. Water rarely punches through a solid wall; it tracks along a jacket, collects in a slack loop, and finds the gland that was hand-tightened instead of torqued. Unused ports need blanking plugs rated to the same level as the enclosure. During inspection, a gland backed off a thread, a jacket worn shiny by movement, or a drip loop running upward instead of down tells you more about real IP performance than the housing label ever will.

Why IP68 ingress protection and explosion protection certification answer different questions

The two claims sit next to each other on the same label, which is exactly why they get mixed up. IP68 is an environmental claim describing what gets into the housing from outside. Explosion protection is a safety claim describing whether the housing can ignite the atmosphere around it, through surface temperature, spark containment, or flame path design. The tests differ, the standards differ, and the bodies issuing the documents differ. A perfectly sealed housing can still be the wrong choice for a flammable atmosphere, and a certified flameproof enclosure is not automatically good at keeping salt spray away from its internals. On the KDQ-EX-PTZ2012IR04N(A), a 2MP explosion proof camera from KAIDUNEX, the published marks include IP68 alongside ATEx, CNEx, CE, and FCC. Read them as separate entries: IP68 for the dust and water question, ATEx and CNEx for the ignition question, CE and FCC for market access and electromagnetic compatibility. When reviewing an explosion proof camera manufacturer's paperwork, ask which certificate covers which claim and confirm the exact model number appears on each. Many explosion proof camera suppliers print every mark on one line, and a buyer who separates them avoids the classic misreading — treating a high IP number as permission to install equipment anywhere.

Conclusion

The digits in IP68 name a class, not a depth, and the class is only as good as the interfaces that reproduce it in the field. When comparing an anti-corrosion PTZ camera housing for a hazardous area, spend your questions on the parts that open: what the gasket is made of and how it is compressed, how the body joint is machined and torqued, which gland and blanking plugs are specified, and what test record backs the rating. Those answers explain why two similarly labelled stainless cameras age so differently. The KDQ-EX-PTZ2012IR04N(A) product information is a useful reference point for how an IP68 stainless housing is described alongside its separate ATEx and CNEx marks.

FAQ

Q: What does the 8 in IP68 mean for a stainless steel camera housing?

A: The 8 covers water, and on a camera housing it means the enclosure passed a continuous immersion test rather than a splash or hose test. In a stainless housing, the shell resists corrosion while the gaskets and cable entries hold the water line, so the digit describes the whole sealed assembly rather than the metal alone. Ask the maker for the depth and duration recorded for the specific model, since the digit fixes the class and the test file carries the number.

Q: Can a damaged cable entry reduce IP68 protection even if the housing body is sealed?

A: Yes. The cable entry is part of the enclosure, so a gland that is loose, mismatched to the cable jacket, or worn lets water track inside even when the body joint is perfectly closed. Inspectors usually find the first sign of trouble at the gland rather than the flange: a backed-off thread, a shiny abraded jacket, or an unused port missing its blanking plug. Fitting the specified gland and torquing it correctly restores the interface, while hand-tightening an old one rarely helps.

Q: Is IP68 the same as ATEX or CNEx explosion protection?

A: No. IP68 answers the dust and water question and is verified as an environmental rating. ATEX and CNEx answer the ignition question for flammable atmospheres, using different standards, different tests, and different certificates. A camera can carry both, as the KDQ-EX-PTZ2012IR04N(A) does, and each claim deserves its own certificate check with the model number confirmed. Suitability for a hazardous area rests on the Ex certificate rather than on the IP number.

Sources / References

IEC 60530:1975/AMD1:1992

IEC 60077-2:1999