Facebook
  • 4MP 33× Explosion‑Proof Fixed Zoom IR Bullet Camera
  • 4MP 33× Explosion‑Proof Fixed Zoom IR Bullet Camera

4MP 33× Explosion‑Proof Fixed Zoom IR Bullet Camera

No.KDC‑EX‑FPLNVa4b33x
KDC‑EX‑FPLNVa4b33x is ATEX, IECEx, CNEX & DNV approved 4MP 33× high‑magnification optical‑zoom explosion‑proof fixed IR bullet camera with built‑in wiper, optimised for on‑shore large‑scale petrochemical tank‑farm and oil‑depot hazardous‑zones. 100‑150 m IR for 24‑h surveillance. 316L stainless‑steel / 304 stainless‑steel IP68 housing,‑40℃~+70℃ wide temp, rich perimeter smart analytics, multi‑power‑supply, optional heater‑fan. For Zone1/2 gas, Zone21/22 dust land‑based hazardous‑locations. Wall‑mount / column‑platform install, requires certified explosion‑proof accessories.
  • 4MP 33× Explosion‑Proof Fixed Zoom IR Bullet Camera

Description

KDC‑EX‑FPLNVa4b33x

4MP 33× Explosion‑Proof Fixed Zoom IR Bullet Camera (Land‑Based Hazardous‑Zone Focus)

KDC‑EX‑FPLNVa4b33x is ATEX, IECEx, CNEX & DNV type‑approved fixed‑mount explosion‑proof IR high‑zoom bullet camera. It is purpose‑built for onshore petrochemical refineries, large‑scale tank farms, chemical parks, on‑shore oil depots, coal‑chemical plants and mine explosive hazardous locations. Equipped with 4MP 1/2.7‑inch CMOS sensor, 33× motorised optical zoom (4.5‑148.5 mm), 100‑150 m long‑range IR illumination. Built‑in explosion‑proof window wiper. 316L stainless‑steel IP68 housing with optional heater‑fan assembly. Multi‑power‑input: PoE+, AC12‑36V, DC12‑57V, AC100‑240V. Operating temperature ‑40 ℃ ~ +70 ℃. Certified for Zone 1/2 gas, Zone 21/22 dust hazardous locations, complying with EPC submission and safety‑acceptance standards for on‑shore petrochemical projects.


🎯 Customer Pain Points

On‑shore large‑scale petrochemical tank‑farms, chemical plants, oil depots and coal‑chemical hazardous‑zone projects face these core challenges:

  1. Mandatory explosion‑proof compliance for hazardous‑area deployment Monitoring devices deployed in Zone 1/2 gas and Zone 21/22 dust hazardous zones must hold valid ATEX / IECEx / CNEX certificates to pass safety assessment, EPC acceptance and periodic safety inspection. Non‑certified equipment is prohibited for field commissioning.
  2. Ultra‑long‑distance fixed‑point inspection for vast industrial sites Large tank‑farms, long pipe‑galleries and loading‑unloading platforms cover extensive areas. Fixed‑position cameras without PTZ require 33× high‑magnification zoom to deliver both wide‑scene overview and close‑up visual inspection of remote valves, storage tanks and process equipment.
  3. 24/7 non‑stop day‑and‑night monitoring requirement Petrochemical and oil‑depot facilities run continuously. Powerful IR supplementary lighting is required for clear imaging under zero‑lux night‑time conditions.
  4. Lens contamination from industrial dust, chemical residues and rainwater Industrial dust, oil‑gas residues and rainwater stain optical surfaces. Manual lens‑cleaning by opening explosion‑proof enclosure is strictly forbidden in explosive atmospheres. Built‑in wiper completes lens cleaning without opening the housing.
  5. Harsh outdoor industrial environmental conditions Sites suffer low‑temperature winters, high‑humidity summers, corrosive chemical vapours and salt‑fog. 316L stainless‑steel housing resists corrosion; optional heater‑fan module ensures stable operation for cold and humid outdoor deployments.
  6. Fixed‑point intelligent perimeter proactive early‑warning Perimeter analytics including cross‑line detection, intrusion, loitering, crowd classification are needed for proactive safety alerts and to reduce manual monitoring workload.
  7. Diversified power‑supply for new‑build & retrofit industrial projects New‑build and revamp projects feature varied power infrastructures. Compatibility with PoE+ and multiple AC/DC power sources simplifies on‑site cabling and renovation.
  8. Platform integration requirements Support mainstream national and international security protocols to connect to existing plant VMS systems and eliminate monitoring data silos.
  9. Project delivery risks for certified explosion‑proof special‑purpose equipment Certified explosion‑proof surveillance hardware has defined production lead‑times. Uncertain delivery may delay petrochemical EPC and plant‑revamp project milestones.

KDC‑EX‑FPLNVa4b33x addresses all above‑mentioned pain‑points: Multi‑certified land‑focused 4MP 33× high‑zoom explosion‑proof fixed IR bullet camera with built‑in wiper, 316L stainless‑steel IP68 housing, wide‑temperature performance, on‑board rich perimeter intelligent analytics and multi‑power‑supply options. Specially designed for fixed‑point 24‑hour hazardous‑zone monitoring for long‑distance observation positions in large‑scale on‑shore petrochemical tank‑farms and oil depots.


🏭 Typical Application Scenarios 

✅ Petrochemical & Chemical Industry: Refineries, large crude‑oil tank‑farms, chemical storage terminals, process production units | Fixed‑point long‑distance monitoring for tank groups, long‑distance pipe‑galleries, pump‑houses and loading‑unloading platforms, Zone 1/2 gas, Zone 21/22 dust locations ✅ Oil & Gas Storage Sites: On‑shore large‑scale oil depots, land‑based LNG storage stations | Long‑range equipment inspection, perimeter security protection, 24‑hour IR night‑vision surveillance ✅ Coal‑Chemical & Heavy‑Duty Industry: Coal‑chemical plants, mine explosive‑classified workshops | Day‑and‑night safety surveillance for explosive hazardous‑zones ✅ Port Hazardous‑Goods Yards: Chemical‑handling port terminals | Salt‑fog‑resistant fixed‑point long‑distance monitoring for on‑shore hazardous‑goods zones

Installation: Wall‑mount or column‑platform multi‑angle adjustable mounting. Must adopt matching ATEX‑certified explosion‑proof cable glands and junction boxes. Compatible with KAIDUNTECH full‑series explosion‑proof accessories to deliver complete end‑to‑end hazardous‑zone monitoring solutions for on‑shore industrial projects.


✨ Core Product Highlights

✅ Full‑Set Authoritative Explosion‑Proof Certifications for Land‑Based Hazardous‑Zones Obtains ATEX, IECEx, CNEX and DNV Type Approval. Explosion‑proof rating: Ex db I Mb; Ex db IIC T6 Gb (Zone 1&2); Ex tb IIIC T80 ℃ Db (Zone 21&22). Complete certification documentation available for EPC submission and safety‑inspection review for petrochemical and heavy‑industry projects.

✅ 4MP High‑Definition 33× High‑Magnification Zoom for Ultra‑Long‑Distance Fixed‑Point Inspection 1/2.7‑inch 4MP progressive‑scan CMOS sensor. 33× motorised optical zoom (4.5‑148.5 mm); FOV H:2.74°‑57.64°, V:1.54°‑34.39°. Complete DORI metrics for person and vehicle targets to support long‑range visual inspection for large tank‑farms and long pipe‑galleries. Features 120 dB WDR, adaptive defog, 3D‑DNR noise reduction, EIS electronic image stabilisation and ICR auto day‑night switch.

✅ 100‑150 m IR Illumination for 24‑Hour All‑Weather Surveillance High‑power infrared supplementary light delivers sharp monochrome images under zero‑lux conditions, ensuring non‑stop fixed‑point monitoring for large‑scale tank‑farms and process‑plant sites during night‑time hours.

✅ Built‑in Explosion‑Proof Window Wiper for Contaminated Industrial Environments Integrated explosion‑proof wiper removes industrial dust, chemical oil residues and rain stains from lens surface. Cleaning is performed without opening explosion‑proof enclosure, eliminating explosion‑hazards caused by manual disassembly in hazardous‑zones and maintaining consistent image clarity.

✅ 316L Stainless‑Steel IP68 Robust Housing & Optional Heater‑Fan Module 316L stainless‑steel enclosure with powder‑coated or electro‑polished surface finish. IP68 dust‑tight and waterproof rating. Optional heater‑fan assembly for low‑temperature, high‑humidity outdoor deployments. Operating temperature:‑40 ℃ ~ +70 ℃, humidity<100 %RH (non‑condensing). Resists corrosive chemical vapours, heavy dust, heavy rainfall and coastal salt‑fog in industrial outdoor conditions.

✅ On‑Board Rich Perimeter Intelligent Analytics for Proactive Safety Alerts Supports region intrusion, cross‑line detection, loitering, crowd‑gathering, fast‑moving‑object detection; human‑vehicle classification, motion‑detection, occlusion‑tampering‑alarm and audio‑anomaly‑detection. ROI enhancement and multi‑area privacy masking are supported to deliver multi‑dimensional proactive safety warnings for tank‑farm and chemical‑plant hazardous‑zones.

✅ Flexible Multi‑Power‑Supply, Rich Protocol & Local‑Storage Compatibility Multi‑mode power‑input: PoE+, AC12‑36V, DC12‑57V, AC100‑240V; max power consumption ≤45 W. Supports H.265 / H.264 / MJPEG triple‑stream encoding. Micro‑SD local storage up to 256 GB for broken‑network recording. Complies with ONVIF S/G/T, GB/T28181, IPv6 and other protocols for seamless integration with third‑party industrial VMS platforms.


📋 Key Specification

Item Parameter
Model KDC‑EX‑FPLNVa4b33x 4MP 33X Explosion‑Proof Fixed Zoom IR Bullet Camera (Land‑Based Hazardous‑Zone)
Sensor 1/2.7‑inch 4MP Progressive‑Scan CMOS
Optical Zoom 33× motorised zoom; focal length 4.5‑148.5 mm
Field of View H:2.74°~57.64°;V:1.54°~34.39°
IR Illumination 100‑150 m effective IR distance
Min. Illumination Color:0.003Lux; B/W:0.002Lux
Image Enhancement Adaptive defog,120dB WDR,3D‑DNR, EIS anti‑shake, ICR day‑night switch
DORI Complete long‑range DORI metrics for person / vehicle targets
Special Mechanical Built‑in explosion‑proof window wiper; Optional heater‑fan module
Smart Events Perimeter intrusion / cross‑line / loitering / crowd‑gathering detection, human‑vehicle classification, motion‑detection, occlusion‑tampering‑alarm, audio‑anomaly‑detection, ROI, privacy mask
Video Encoding H.265 / H.264 / MJPEG triple‑stream encoding
Local Storage Micro‑SD up to 256 GB, broken‑network supplementary recording
Protocol ONVIF S/G/T, GB/T28181, TCP/IP family protocols, IPv6 supported
Power Supply PoE+, AC12‑36V, DC12‑57V, AC100‑240V optional; ≤45W
Explosion‑Proof Grade Ex db I Mb; Ex db IIC T6 Gb(Zone1&2); Ex tb IIIC T80℃ Db(Zone21&22)
Certifications ATEX, IECEx, CNEX, DNV Type Approval
Housing 316L stainless‑steel / 304 stainless‑steel; powder‑coated / electro‑polished optional
Ingress Protection IP68
Operating Environment ‑40 ℃ ~ +70 ℃, humidity <100 %RH non‑condensing
Cable Entry M25×1.5
Dimension(L×W×H) 440 × 188 × 180 mm
Net Weight ≤10.2 kg
Installation Wall‑mount / Column‑platform multi‑angle adjustable mounting

📦 Lead‑Time & Warranty Terms

Item Details
Standard Model 3‑4‑week production lead‑time upon deposit receipt
Custom‑modified Version 5‑6‑week lead‑time for surface‑finish, heater‑fan configuration, interface or software‑feature adjustments

Deliverables: Datasheet, mechanical dimension drawings, copies of ATEX/IECEx/CNEX/DNV certificates, operation manual for petrochemical / heavy‑industry EPC project review and safety‑acceptance submission.

Warranty Terms ‑ 12‑month standard full‑unit warranty. Extended warranty duration negotiable via separate commercial quotation. ‑ Defective hardware supports factory‑return repair or replacement service. ‑ Value‑added support: remote configuration‑guidance, complete technical‑document support for on‑shore hazardous‑zone surveillance new‑build and reconstruction projects.

Packaging & Logistics: Export‑grade wooden‑crate packaging. Supports EXW, FOB and other international‑trade terms. Consolidated shipment available with explosion‑proof accessories and recording equipment.

⚠️ Reminder: KDC‑EX‑FPLNVa4b33x is multi‑certified 33× high‑zoom explosion‑proof fixed IR bullet camera with wiper, optimised for on‑shore petrochemical, oil‑depot, mine and port hazardous‑zone deployment. Off‑the‑shelf stock cannot be guaranteed. Please place orders sufficiently ahead of project milestones. Installation must strictly adopt ATEX‑qualified explosion‑proof cable‑glands & junction boxes and comply with local hazardous‑area safety‑regulations.


📝 Reference Success Stories

Case 1 | Large Petrochemical Wide‑Span Tank‑Farm Fixed‑Point Long‑Distance Surveillance Project

‑Project Challenges: New‑build large‑scale petrochemical tank‑farm project for Zone 1/2 and Zone 21/22 hazardous‑zones. Require certified fixed explosion‑proof IR zoom cameras; 33× high‑magnification zoom for long‑distance inspection of tanks and valves; 100‑150 m IR for 24‑h monitoring; built‑in wiper against dust‑rain contamination; optional heater‑fan for outdoor temperature fluctuation; multi‑power‑supply options; corrosion‑resistant 316L IP68 housing. Equipment documentation required for hazardous‑zone safety‑inspection and EPC acceptance, integration with existing plant VMS. ‑Solution: Deploy KDC‑EX‑FPLNVa4b33x explosion‑proof fixed IR zoom bullet cameras on tank‑farm support‑pillars with column‑platform mounting. Equip certified explosion‑proof cable‑glands and junction boxes, configure wiper schedule and intelligent detection rules, integrate with plant security platform. ‑Outcome: Complete explosion‑proof certification satisfies petrochemical hazardous‑zone acceptance criteria. 33× high‑zoom plus IR delivers reliable day‑and‑night long‑distance fixed‑point inspection for key wide‑span tank‑farm assets. Built‑in wiper maintains lens clarity under dusty outdoor conditions. Perimeter smart analytics enhances site safety risk‑alerting. Project successfully passed hazardous‑zone safety‑acceptance.

Case 2 | Coastal Large‑Scale Oil‑Depot Hazardous‑Zone Surveillance‑System Reconstruction Project

‑Project Challenges: Revamp project for in‑service coastal on‑shore large oil depot. Require fixed‑point explosion‑proof zoom IR cameras for tank‑group hazardous‑zones, supporting long‑distance zoom night‑vision monitoring and wiper cleaning. Compatibility with existing monitoring platform for periodic safety‑inspection. ‑Solution: Wall‑mount deployment of KDC‑EX‑FPLNVa4b33x explosion‑proof cameras with network adaptation and smart‑event configuration. ‑Outcome: Stable fixed‑point day‑and‑night long‑distance monitoring for oil‑depot hazardous‑zones. Integrated wiper adapts to coastal rain‑dust operating environment. Revamp project completed safety‑acceptance.


❓ FAQ

Q1: Which hazardous zones is this camera applicable to for land‑based projects? A: It holds ATEX, IECEx, CNEX and DNV Type Approval. Ex db I Mb; Ex db IIC T6 Gb for Zone 1 & 2 gas hazardous‑zones; Ex tb IIIC T80 ℃ Db for Zone 21 & 22 dust hazardous‑zones. Certification documents can be provided for petrochemical and oil‑depot EPC review and safety‑inspection submission.

Q2: What benefits does 33× high‑magnification zoom bring for land‑based large‑scale tank‑farm fixed‑point scenarios? A: 33× motorised high‑magnification zoom (4.5‑148.5 mm) enables flexible field‑of‑view switching between wide overview and long‑distance close‑up observation. 100‑150 m IR illumination delivers clear night‑time imaging for fixed‑point positions in wide‑span tank‑farms and process‑units, achieving dependable 24‑hour surveillance without PTZ rotating mechanism.

Q3: Why built‑in wiper for on‑shore industrial sites? A: On‑shore petrochemical and oil‑depot sites accumulate industrial dust, chemical residues and rain‑water stains on optical windows. The explosion‑proof wiper cleans lens without opening the housing, removing explosion‑safety risks from manual disassembly inside hazardous‑zones and sustaining clear imaging in polluted outdoor industrial environments.

Q4: What intelligent functions meet perimeter‑safety needs for industrial fixed‑point sites? A: Supports cross‑line detection, region intrusion, loitering, crowd‑gathering detection, human‑vehicle classification, motion‑detection, occlusion‑tampering‑alarm and audio‑anomaly‑detection. Provides proactive safety early‑warning for fixed‑point monitoring positions of tank‑farms and production‑unit hazardous‑zones.

Q5: What optional configurations are available for outdoor land‑based deployment? A: Optional heater‑fan module for low‑temperature / high‑humidity outdoor locations; powder‑coated or electro‑polished housing surface finishes. Please specify requirements at inquiry.

Q6: Are power‑supply options suitable for new‑build & revamp industrial plants? A: Multi‑input power‑supply: PoE+, AC12‑36V, DC12‑57V, AC100‑240V, max power consumption ≤45 W. Adapts to varied power‑supply conditions for new‑build and retrofit industrial‑sites.

Q7: What installation recommendations for land‑based hazardous‑zones? A: Supports wall‑mount and column‑platform multi‑angle adjustable mounting, suited for plant outer‑walls, tank‑farm support‑pillars and equipment‑frames. Must use matching ATEX‑certified explosion‑proof cable‑glands and junction boxes, strictly comply with local hazardous‑area installation‑specifications.

Q8: Recommended accessories & customisation support? A: Recommended accessories: KDR‑1500 Rubber Flexible Hose, KDSR‑1500 Stainless‑Steel Flexible Hose, EX‑KDP001 Explosion‑proof connector, KDJ004 / KDJ008 Explosion‑proof junction box, KDB006T anti‑shake stainless‑steel bracket. Custom‑orders for surface‑finish, heater‑fan, interfaces and software‑features are available, 5‑6‑week lead‑time upon requirement confirmation.

Q9: Environmental‑operating parameters for on‑shore outdoor deployment? A: Operating temperature:‑40 ℃ ~ +70 ℃; humidity below 100 %RH(non‑condensing); IP68 ingress‑protection. 316L stainless‑steel housing withstands industrial corrosive‑vapour, heavy dust, heavy‑rain and coastal salt‑fog outdoor conditions.


📎 Optional Accessories List

‑ KDR‑1500 Rubber Flexible Hose ‑ KDSR‑1500 Stainless Steel Flexible Hose ‑ EX‑KDP001 Exd Type Explosion‑proof connector ‑ KDJ004 Exe Type Explosion‑proof Junction Box ‑ KDJ008 Exe Type Explosion‑proof Junction Box ‑ KDB006T Anti‑Shake Stainless‑Steel Bracket

Download