Facebook
  • Explosion Proof Hi-fidelity Pickup
  • Explosion Proof Hi-fidelity Pickup

Explosion Proof Hi-fidelity Pickup

No.KDPICKUP
ATEX‑qualified omnidirectional explosion‑proof sound pickup, 304 stainless‑steel IP68 housing. 70 m² pickup coverage, up to 3000 m audio transmission, DC12V, built‑in pre‑amplifier. For Zone 1‑2 & Zone 21‑22 hazardous‑area high‑fidelity audio‑collection, matching explosion‑proof surveillance cameras for refineries, offshore rigs and vessels.
  • Explosion Proof Hi-fidelity Pickup

Description

Explosion‑Proof Sound Pickup

ATEX‑qualified explosion‑proof omnidirectional audio pickup, 304 stainless‑steel housing with IP68 rating. Ex marking Ex db ⅡC T6 Gb / Ex tb IIIC T80 °C Db. Wide‑frequency‑response omnidirectional sound‑collection, effective pickup coverage up to 70 m², long‑distance audio transmission up to 3000 m. DC12V powered, built‑in pre‑amplifier circuit. Designed for gas Zone 1‑2 and dust Zone 21‑22 hazardous‑area sites including refineries, petrochemical plants, offshore rigs, FPSO and vessels, to realise high‑fidelity on‑site audio collection for explosion‑proof surveillance camera systems.

🎯 Customer Pain Points

Hazardous‑industry and marine‑offshore surveillance projects face audio‑acquisition challenges:

  1. Audio‑collection limitation inside hazardous zones: Ordinary non‑Ex microphones / pickups cannot be deployed in classified gas‑dust hazardous locations. Installing non‑certified audio devices within Zone 1‑2 / Zone 21‑22 will trigger safety‑audit or vessel‑survey rejection.
  2. Demanding on‑site acoustic environment: Industrial and marine sites contain heavy background noise. Projects require high‑SNR omnidirectional pickup to capture clear human‑voice and equipment‑operating sound without signal distortion.
  3. Long‑distance audio‑transmission requirement: In large‑scale refineries and offshore platforms, the pickup installation point is far from recording equipment. Common pickups suffer signal attenuation over long‑cable runs, needing reliable long‑range audio‑transmission capability.
  4. Corrosion‑resistant outdoor / deck deployment: Off‑shore salt‑spray and coastal chemical vapour erode ordinary plastic or thin‑metal microphones. Robust stainless‑steel Ex‑enclosure is required for open‑deck and outdoor hazardous‑locations.
  5. System‑matching requirement: Explosion‑proof surveillance cameras need matching ATEX‑certified sound‑pickup to build complete video‑plus‑audio surveillance solution. Mixing non‑Ex audio accessories invalidates whole‑set hazardous‑zone acceptance.
  6. Uncertain project lead‑time: ATEX‑certified explosion‑proof sound pickup is special hazardous‑area audio accessory. Ambiguous delivery cycles may delay surveillance‑system commissioning milestones.

This explosion‑proof sound pickup solves above‑mentioned pain‑points. ATEX‑certified 304 stainless‑steel omnidirectional audio‑collecting device with built‑in pre‑amplifier. It delivers high‑fidelity long‑distance audio acquisition for hazardous‑area explosion‑proof video‑surveillance systems.

🏭 Typical Application Scenarios(Land‑Hazardous & Off‑Shore Marine)

✅ Refineries & Petrochemical Plants: Hazardous‑zone on‑site sound collection for explosion‑proof camera surveillance systems within gas Zone 1‑2 / dust Zone 21‑22. ✅ Off‑shore Rigs & FPSO Units: Salt‑fog offshore hazardous‑area audio acquisition for safety monitoring and equipment‑sound recording. ✅ Oil Tankers & Special Work‑Vessels: Vessel‑deck hazardous‑cargo‑zone sound pickup, paired with ship‑borne explosion‑proof surveillance cameras. ✅ Coastal Chemical Terminals: Hazard‑classified process‑area high‑fidelity audio collection under salt‑spray corrosive atmosphere.

3‑wire connection (power, audio, GND). Supports wall‑mount installation. Compatible with KAIDUNTECH explosion‑proof cameras, flexible hoses and junction boxes for complete video‑and‑audio hazardous‑area surveillance solution.

✨ Core Product Highlights

  • Authoritative Explosion‑Proof Qualification: Ex marking: Ex db ⅡC T6 Gb / Ex tb IIIC T80 °C Db. Suitable for gas Zone 1‑2 and dust Zone 21‑22 hazardous‑locations. Certification documents are available for land‑site safety‑audit and offshore‑vessel survey submission.
  • High‑fidelity Omnidirectional Audio Performance: Omnidirectional sound‑collecting pattern, frequency‑response 20 Hz‑20 kHz, sensitivity‑34 dB, max sound‑pressure 120 dB SPL. Effective pickup coverage area up to 70 m², built‑in pre‑amplifier circuit supporting direct headphone drive. Realises clear on‑site voice and equipment‑sound acquisition under complex industrial acoustic‑conditions.
  • Ultra‑long‑distance Audio Transmission: Supports audio‑signal transmission up to 3000 metres, solving signal‑attenuation trouble for large‑size plant and offshore‑platform long‑cable‑layout projects. 600 Ohm non‑balanced output, 2.5 Vpp /‑25 dB output‑amplitude, stable analog‑audio output.
  • Robust 304 Stainless‑Steel Enclosure: 304 stainless‑steel housing, IP68 ingress‑protection grade. Operating temperature‑40 ℃ ~ +60 ℃, adapts outdoor‑industrial and open marine‑deck corrosive environment. Net weight 1.5 kg for convenient field‑mounting.
  • Stable Power‑supply & Simple Wiring: DC12V power‑input, 3‑lead wiring definition: power supply, audio signal, common‑ground. Outlet‑hole specification 20*1.5 mm, easy to mate with explosion‑proof cable‑glands for hazardous‑area field‑wiring.
  • System‑matching Accessory: Purpose‑built to pair with KAIDUNTECH full‑series explosion‑proof surveillance cameras. Forms fully‑certified video‑and‑audio surveillance solution, simplifying project safety‑acceptance work.

📋 Key Specification

Item Parameter
Model Explosion‑Proof Sound Pickup
Explosion‑Proof Mark Ex db ⅡC T6 Gb / Ex tb IIIC T80 °C Db
Material 304 Stainless Steel
Protection Grade IP68
Pick‑up Coverage Up to 70 square meters
Max Audio Transmission Distance 3000 m
Sensitivity ‑34 dB
Frequency Response 20 Hz ~ 20 kHz
Directivity Omnidirectional
Signal‑to‑Noise Ratio 60 dB(1 m 40 dB SPL); 40 dB(10 m 40 dB SPL) @1 kHz 1Pa
Dynamic Range 70 dB (@1 kHz Max dB SPL)
Max Sound Pressure 120 dB SPL (1 kHz, THD 1%)
Output Impedance 600 Ohm non‑equilibrium
Output Signal Amplitude 2.5 Vpp /‑25 dB
Circuit Built‑in pre‑amplifier (direct headphone‑drive capable)
Connection 3‑leads: power supply, audio, GND
Power Supply DC12V
Cable Outlet Hole 20*1.5 mm
Net Weight 1.5 kg
Working Environment ‑40 ℃ ~ +60 ℃
Installation Method Wall‑mount

📦 Lead‑Time & Warranty Terms

  • Standard Model: 3‑4‑week production lead‑time upon receipt of deposit.
  • Custom‑modified Version: 5‑6‑week lead‑time for custom outlet‑hole size or special surface‑treatment requirements.

Deliverables: Datasheet, dimension drawings, explosion‑proof certificate copies and installation manuals for project‑review and vessel‑survey submission.

Warranty Terms: 12‑month standard warranty for the complete unit. Extended‑warranty service available upon separate commercial quotation. Remote field‑installation technical‑guidance is provided.

Packaging & Logistics: Export‑grade wooden‑crate packaging. Supports EXW, FOB and other trade terms; can be consolidated shipment with explosion‑proof‑camera orders.

Reminder: Explosion‑proof sound pickup is special hazardous‑area audio safety accessory. Off‑the‑shelf stock cannot be guaranteed. Please place orders ahead of project construction & commissioning milestones.

📝 Reference Success Stories

Case 1 | Inland Refinery Hazardous‑Area Video‑Audio Surveillance Project ‑Project Challenges: Inland refinery Zone 2 hazardous‑zone. Existing explosion‑proof‑camera surveillance system needs certified audio‑collection device for on‑site voice and equipment‑sound recording; long‑cable layout between pickup and recording‑room, must pass local safety‑authority acceptance. ‑Solution: Deploy explosion‑proof sound pickups, matched with explosion‑proof junction boxes and flexible hoses. ‑Outcome: Omnidirectional high‑fidelity audio acquisition, stable signal transmission over long‑distance cable. Realises synchronised video‑and‑audio monitoring and successfully passed hazardous‑zone safety‑audit acceptance.

Case 2 | FPSO Off‑shore Platform Hazardous‑Zone Surveillance Upgrade Project ‑Project Challenges: FPSO offshore‑platform heavy salt‑spray corrosive‑environment. Require ATEX‑certified sound‑pickup for hazardous‑deck audio‑collection paired with explosion‑proof cameras; must pass platform safety‑audit. ‑Solution: Install explosion‑proof sound pickups with complete set of anti‑corrosion wiring accessories. ‑Outcome: 304 stainless‑steel housing resists offshore salt‑fog corrosion. Captures clear on‑site audio‑signal and completed FPSO project safety‑acceptance.

❓ FAQ

Q1: Which hazardous zones can this explosion‑proof sound pickup apply to? Are Ex‑certificate documents available for vessel‑survey submission?

A: According to Ex‑marking, it is applicable for gas Zone 1‑2 and dust Zone 21‑22 hazardous‑locations. Explosion‑proof certification documents can be provided for land‑safety‑audit and offshore‑vessel‑survey review.

Q2: What is the maximum audio‑transmission distance?

A: Up to 3000 metres analog‑audio‑transmission, suitable for large‑size plants and offshore‑platform long‑cable‑layout scenarios.

Q3: What does omnidirectional pickup mean?

A: Omnidirectional pattern collects sound equally from all directions of 360°, covering the whole monitoring area without strict angle‑alignment requirement during installation.

Q4: What accessories can be matched together?

A: Compatible with KAIDUNTECH explosion‑proof cameras, explosion‑proof flexible hoses and junction boxes, forming complete video‑and‑audio hazardous‑area surveillance solution.

Q5: What after‑sales support do you offer?

A: Standard 12‑month full‑unit warranty. Remote installation‑guidance is provided. Extended‑warranty quotation is available upon request.




Product Overview

A camera shows a relief valve venting at three in the morning, but it cannot tell you whether the hiss is routine or the first sign of a passing gasket. This pickup adds the missing channel: it listens where the camera looks, and it does so from inside the classified area instead of from a safe room a hundred metres away. On a wall-mount pattern, it goes onto a column, a bulkhead or a structural leg without a fabricated bracket. Orders usually come from the people who have to close out the paperwork: electrical and instrumentation teams at refineries, offshore operators, shipyards fitting tankers, and integrators building a cabinet list. As explosion proof camera manufacturers, we build this pickup as a dedicated hazardous-area audio unit, not a room microphone adapted for the job. It is made to sit on the same junction box and wiring route as the explosion proof cameras on that structure, which means audio and video share one wiring standard and one acceptance conversation at handover. In daily use the recording side simply receives a line-level signal: voices at a loading point, a pump whose note changes before it trips, an alarm that never reached the control-room log. That is the difference between footage you review after an incident and a record you can act on while it is still happening. Audio is often the last item on the drawing. A carefully planned explosion proof camera solutions package loses the sound channel when the cabinet list is trimmed, and it comes back a year later as a variation with no cable route reserved for it. Ordinary microphones have no place in a classified area. A standard industrial microphone or a camera's built-in mic is not built for Zone 1-2 or Zone 21-22, so placing one there is a problem before the system is even switched on. The site is loud before anyone speaks. Compressors, pumps and venting steam lift the noise floor, and a pickup with poor signal-to-noise performance hands you a wash of machinery with the voices buried somewhere inside it. Salt spray and chemical vapour take housings apart. Plastic bodies and thin metal grilles corrode on an open deck, which is why the enclosure has to be specified the way you would specify an explosion proof camera housing rather than a room microphone. Mixed paperwork stops the handover. When the camera side is complete and the audio accessory cannot stand beside it on the same schedule, the cabinet is rejected as a whole; video and sound have to be reviewed together. Audio usually arrives late. It lands on the drawing after the positions are settled, so the pickup has to suit a mounting point, a cable route and a shutdown window that were all agreed for an explosion proof industrial camera months earlier.

Explosion-Proof Rating and Zone Coverage

Gas hazardous areasZone 1 and Zone 2
Dust hazardous areasZone 21 and Zone 22
Gas group coverageIIC, which also covers IIA and IIB atmospheres
Temperature classT6 for gas; 80 °C maximum surface temperature for dust
Equipment markingEx db IIC T6 Gb / Ex tb IIIC T80 °C Db
Protection conceptsFlameproof enclosure (db) for gas; dust protection by enclosure (tb)
Handover documentsExplosion-proof certificate copies, datasheet and dimension drawings for safety audit and vessel-survey submission, filed alongside the hazardous area camera paperwork

Audio Performance and Long-Run Signal

Omnidirectional means there is no aiming step. Sound is collected across a full 360°, so a fitter working behind the mounting column is captured as clearly as someone standing in front of it, and commissioning does not depend on an angle somebody guessed at during the survey. The band covers speech, machinery notes and the low-frequency rumble that tells you a compressor is unhappy, and the sensitivity leaves enough output to work without an outboard pre-amplifier. Signal-to-noise is where most industrial audio installations fail. This unit holds 60 dB at one metre and 40 dB at ten metres at 1 kHz, 1 Pa, with 70 dB of dynamic range — enough separation to hear a voice over a running pump set, and enough headroom to keep a close-range shout from flattening into distortion. Long cable runs are the other half of the job. The output carries up to 3000 m to the recording equipment, so a pickup on a jetty head, or one mounted beside marine grade cctv cameras on a far module, reaches the equipment room without an intermediate amplifier. The pre-amplifier does its work at the pickup end and can drive headphones directly at the test point, while at the recorder the signal arrives as a conventional analogue input that slots into the explosion proof camera solutions already on site.

Mounting, Wiring and System Build

  1. Fix the wall-mount position.
  2. Height, ladder access and distance from wash-down spray matter more than a millimetre; treat it as you would the mounting decision for an explosion proof industrial camera on the same structure.
  3. Check the temperature band. The unit is rated from -40 °C to +60 °C, which covers an exposed deck in winter and a hot module roof in summer but not the inside of a fired heater box; if your location runs hotter, talk to us before you drill.
  4. Bring the cable in through the outlet. The 20*1.5 mm outlet accepts an Ex-rated cable gland, and as with an explosion proof camera housing, the gland's protection concept should match the enclosure's.
  5. Terminate the three leads.
  6. Power supply, audio and ground are the whole connection, and the DC12V supply feeding them must itself be suitable for the zone.
  7. Build the run with matching accessories.
  8. An explosion-proof junction box and a flexible hose between pickup and box keep vibration off the thread ports, and matching the explosion proof cameras on the same circuit keeps one accessory standard across the cabinet.
  9. Commission at the recorder.
  10. Check level, listen for mains hum or an earth loop, and log the audio channel next to the video so the handover shows a complete system rather than industrial surveillance cameras with an unexplained cable beside them.

Applications and Field Deployments

  • Refineries and petrochemical plants.
  • Process-unit audio on the same structures as the explosion proof industrial camera watching the unit, so an operator hears a steam leak or a lifting relief valve while looking at the flare area.
  • Offshore rigs and FPSO units.
  • Deck and module audio through salt fog, where 304 stainless steel and IP68 sealing — the same specification you would ask for on an explosion proof camera housing — decide whether the unit is still working in its second season.
  • Oil tankers and special work vessels.
  • Manifold and hose-handling positions, where the sound of a coupling being made or a winch under load tells the deck officer more than the picture alone; it sits beside marine grade cctv cameras on the same bulkhead.
  • Coastal chemical terminals.
  • Jetty heads and loading arms, where vapour and salt air attack ordinary housings and where an audio record settles loading-time disputes; it works in the same classified footprint as the hazardous area camera on the arm.
  • Inland refinery, Zone 2 retrofit.
  • Pickups added through explosion-proof junction boxes and protected cable routes to an installation that was already commissioned; the long run back to the recording room held a stable signal and the work passed hazardous-area acceptance.
  • FPSO deck upgrade.
  • Hazardous-area pickup and anti-corrosion wiring accessories fitted as an extension to the industrial surveillance cameras already on the platform, capturing deck audio through a heavy salt-spray season and closing out the safety audit.

Specifications

The 600 Ohm non-balanced output provides a 2.5 Vpp / -25 dB output amplitude for stable analog audio.

SpecificationDetail
ModelExplosion-proof sound pickup (KDPICKUP)
Housing material304 stainless steel
Protection gradeIP68
Pick-up coverageUp to 70 m²
Frequency response20 Hz ~ 20 kHz
DirectivityOmnidirectional
Sensitivity‑34 dB
Max sound pressure120 dB SPL (1 kHz, THD 1%)
Output impedance600 Ohm non‑equilibrium
Output signal amplitude2.5 Vpp /‑25 dB
CircuitBuilt‑in pre‑amplifier (direct headphone‑drive capable)
Connection3‑leads: power supply, audio, GND
Power supplyDC12V
Net weight1.5 kg

Ordering, Lead Time and Warranty

  1. Send the site details.
  2. Zone and gas or dust group, mounting point, distance to the recording room and the accessories already on your drawing — we check the configuration against them before production starts.
  3. Place the order.
  4. Standard build runs 3-4 weeks from receipt of deposit; a version with a different outlet-hole size or a special surface treatment runs 5-6 weeks.
  5. Receive the document pack.
  6. Datasheet, dimension drawings and installation manuals travel with the unit for project review and handover — the same documentation set we prepare on every order as explosion proof camera manufacturers, from a single pickup to a full explosion proof camera solutions package.
  7. Arrange shipment.
  8. Export-grade wooden crate packing, EXW or FOB terms, and consolidation with a marine grade cctv cameras order so the deck cabinet arrives in one delivery.
  9. Hand over with support.
  10. Twelve months of warranty on the complete unit, extended cover on a separate quotation, and remote technical guidance through installation and commissioning.
  11. Order against your milestones.
  12. This is a built-to-order hazardous-area accessory rather than a stock item, so off-the-shelf availability cannot be guaranteed — place the order ahead of the construction and commissioning dates.

Technical Support & Model Matching

Tell us your site conditions, hazardous-zone classification and the distances you need to cover, and our engineering team will help you match the right model and configuration before you place an order. Our R&D team, in-house assembly workshop and finished-product testing area take every unit through a 72-hour test before delivery, while our network of 50 overseas strategic partners can advise on local installation and commissioning. Troubleshooting is handled around the clock, 365 days a year.

FAQ

Which hazardous zones can this sound pickup be installed in, and can I get the certificate copies for a vessel survey?

It is marked for gas Zone 1 and Zone 2 and for dust Zone 21 and Zone 22, with IIC gas group coverage and a T6 temperature class, so it can sit in the same classified footprint as the hazardous area camera on the same structure. Yes — the handover documents travel with the unit for that submission.

How far can the audio signal run before I need an amplifier?

Up to 3000 m of cable between the pickup and the recording equipment on the analogue output, which is what makes it usable on a jetty head, a far process module or a deck position with the recorder in a central equipment room. If your route is longer than that, send us the layout before the cable is pulled so the arrangement can be checked first.

What does omnidirectional pickup mean for where I mount it?

Sound is collected across 360° rather than through a narrow cone, so there is no aiming step during commissioning and no penalty for mounting on a column between two work areas. Choose the position by where the sound actually happens — a manifold, a pump bay, a loading arm — and the person working behind the housing is still captured.

Which accessories do I need to complete the audio point?

An explosion-proof junction box, Ex-rated cable glands at each entry, and the vibration isolation called out in the mounting steps. These are the same accessories used on the camera side of the cabinet, which keeps the audio and video ends on one acceptance walk-through.

What support is available after the unit is delivered?

Mounting, wiring and level-setting questions go to the team that builds the unit, and remote guidance is available while your installer is on site. As explosion proof camera manufacturers, we can also confirm marking, zone and cable-entry details in writing if your surveyor asks for them before the installation is signed off.

Can I add this pickup to cameras that are already commissioned?

Yes. It is a standalone analogue audio device on its own three leads, so it can be added to existing explosion proof cameras without touching the video configuration — the recorder simply gains an audio channel. That is how most zone-by-zone expansions are handled once a plant or a vessel is already in service.

Will the audio channel interfere with the video or the network?

No. The pickup runs on its own three-lead analogue connection and does not share the IP network with the industrial surveillance cameras on site, so a fault on one side does not take out the other. Keep the audio cable routed clear of variable-frequency drive cabling, as you would with any analogue signal.

Download